Showing Dashboard for Thu September 25th, 2025
Data recorded in Copenhagen (GMT+02:00) time

Vitality

79.44
AHI
59.87
Leak rate
100
Usage
98.01
O2 score
N/A

Vitality

Bottom

4.69%

of all users

AHI
0.1%
Leak rate
Top 0.01% of all users
Usage
Top 5.86% of all users
O2 score
N/A

Apnea Hypopnea Index

12.35

Increased by 3.84

Average Pressure

18.36

Decreased by 0.01

Average Leak Rate

1.95

Decreased by 0.14

Daily Usage

6h 48m

by

    AHI

    Average for 1 night (3 sessions)

    .......

    Machine Settings

    S9 Lumis VPAP 150 ST-A

    Mode Bilevel-s/t
    Mask Pillows
    EPAP 8.6 cmH₂O
    Humidity level 3
    Ramp pressure 6 cmH₂O
    Ramp time 5.0
    Mask ResMed AirFit F40
    More...

    Statistics

    Usage Statistics

    Min Med 95% 99.5%
    Pressure 16.02 18.4 18.4 18.4
    Epap 6.22 8.6 8.6 8.6
    Leak rate 0.0 2.4 3.6 7.2
    Resp rate 7.6 11.0 12.2 15.2
    Flow limit 0.0 0.0 0.0 0.0
    More...
    Time in apnea: 13m 23s (3.28%)
    Large leak: 2s (0.01% )

    Mask

    The mask used on this date

    ResMed AirFit F40 Full Face Mask (large)
    Purchased:
    6 months ago
    AHI: 6.453
    |
    Leak: 3.445
    |
    Pressure: 18.236
    Pressure
    Breathing
    Leak Rate
    Flow Limit
    Snore
    SpO2
    Pulse Rate
    Movement
    Sleep Stage