Showing Dashboard for Wed February 1st, 2023
Data recorded in Brisbane (GMT+10:00) time

Apnea Hypopnea Index

1.08

Increased by 0.37

95% Pressure

12.48

Increased by 0.1

95% Leak Rate

4.8

Increased by 1.2

Daily Usage

8h 21m

by

    AHI

    Average for 1 night (1 session)

    .......

    Machine Settings

    AirSense 10 AutoSet (37028)

    Mask Full Face
    Mode APAP
    Pressure min 10.0 cmH2O
    Pressure max 14.0 cmH2O
    EPR level 3 cmH2O
    Humidity level 2
    Ramp Off
    Ramp pressure cmH2O
    More...

    Statistics

    Usage Statistics

    Min Med 95% 99.5%
    Pressure 10.0 11.14 12.48 13.58
    Epap 7.0 8.14 9.48 10.58
    Leak rate 0.0 2.4 4.8 13.2
    Resp rate 7.0 15.8 22.2 30.6
    Time in apnea: 1m 16s (0.25%)
    Large leak: 42s (0.14%)
    Pressure
    Breathing
    Leak Rate
    Flow Limit
    Snore
    SpO2
    Pulse Rate
    Movement
    Sleep Stage